1.
Indicator |
The dome type indicator is directly mounted
on the center column to provide positive visual indication
of the valve position even over long distances.
|
2.
Capacitor
|
3. Terminal
Block |
Quality terminal block containing segregated
power and control terminals are designed for use in high vibration
environments.
|
4. Limit Switch
&Torque Switch |
One each for Open and Closed.
|
5. Body |
6. Base
|
7. Drive Bushing |
8. Window |
9. Motor |
Squirrel caged induction motor is torally enclosed
type with high stall torque and low inertia force to suit
seating/ unseating of valves.
Integral thermal protection to prevent damage to the single/
three phase motor.
|
10. Heater |
11. Hand Wheel
|
12.
Manual Override |
Hand/Auto declutching lever for engagement
of handweel.
The power drive is automatically resorted by the motor starting.
|
13.
Lever
|
14.
Worm Gear |
The precision worm and worm wheel mechanism
transfers
high torque with high efficiency and low sound level( Max.5
0d B) even though small in size.
Additional benefits include low backlash and longer life.
Various output torques(60Nm~2,500Nm) cater for valves from
2" to 24".
|
|
|
|
|
|
|
|
|
|
|
|
Standard enclosure with o-ring sealing is watertight to IECIP67,
NEMA4 and 6.The actuator is available with optional explosion
proof enclosure.
|
|
|
|
Electric wrring of control circuit is standardized for single
and three phase power supply in a single module. Multiple
terminal contacts sufficiently cover additional requirements
such as auxiliary contacrs for DCS, interlocking and other
options.
|
|
|
|
|
|
Mechanical and electrical module can be separated easily
to improve assembling, maintenance and alteraton of eletrical
requirements. Actuator has enough internal space for optional
accessories.
|
|
|
|
|
Size of handwheel is designed for safe and efficient emergency
manual operation.
|
|
|
|
Hand / auto declutching lever for handwheel engagement. The
power drive is automatically restored by motor start.
|
|
|
|
Base mounting is standard to ISO 5211. Drive bush is removable
for machining to valve stem requirement. The actuator position
on the valve can be selected for 4 positions by means of 4
bolt holes in the drive bush.
|
|
|
|
A space heater inside the actuator prevents condensation
due to temperature and weather changes. Standard 200W heater
keeps all electrical components in the actuator clean and
dry.
|
|
|
|
The limit switch is acticated by means of a simple and yet
reliable cam mechanism mounted and driven by the center column.
The valve position can be accurately and easily set with the
simple adjustable switch mechanism. The set position is permanent
and is not affected by over-travel resulting form manual operation.
|
|
|
|
Cam activated torque switches are easily adjustable to provide
over-load protection.
|
|
|
|
Rolled steel wormgear on aluminium bronze wormwheel self-locks
to prevent valve back drive on control signal or power failure.
|
|
|
|
|
|
|
|
|
|
|
Providing the dry contact signal
to check valve's positions (cam switches structure). |
|
|
|
Providing the dry contact signal
send to customer's panel as fault signal (cam switches
structure). |
|
|
|
|
Combined with PIU and transfer
output signal
(DC : 4~20mA) from PIU's value of resistance power : AC
110/220V¡¾10% 50/60Hz DC24V output signal : DC 4~20mA |
|
|
|
|
|
Combined with PIU and control the valve's position
proportionally by input signal and provide valve's
position as their output signal. |
|
Input signal : DC 4~20mA/DC 2~10V/DC 1~5V |
Output signal : DC 4~20mA |
Power : AC 110/220V¡¾10% 50/60Hz DC24V |
Size : 120mm¡¿135mm |
Operating temperature : -10¡É~55¡É |
Resoluting : Min. 1/500 |
Operating Humidity :
90% RH Max.(Non condensing) |
|
|
|
Applicable Function
- |
Auto Scan-Automatically
memorized each open/close position by the
signal of PIU.(It is very easey to set the
PCU even in local area only requiring one
push of the Auto Scan button)
|
- |
Fail close-Drive to close
position there is no certain input signal
|
- |
Fail open-Drives to open
position there is no certain input signal
|
- |
Manual operation mode-Zero
Null/Span Open
|
- |
Operational Setting-It is
possible to fix a certain signal as Open
and Close.
|
- |
Manual Operating-Locally
move valve's position without source of
signal by direct use of dip switch on PCU
board
|
|
|
|
|
|
|
A small unit that is mounted to the actuator to operate the
valve's position in local. Local/Remote switch Open/Stop/Close
switches
|
|
Rugged structure with special parts (Explosion proof type
Selector, pushbutton switches) Guarantees that watertight
and safety working in hazardous environments.
|
|
|
|
|
|
Providing resistnace value (0~1K§Ù) according to valve's position.
|
|
|
|
|
|
|
Combined transformer with electric contactor
and directly provides various control voltages
to the Actuator(24VDC, 110VAC/220VAC) from
main power (380VAC/440VAC).
|
|
|
|
|
|
|
|
TYPE
|
Max Output Torque
|
Operating Time 60/50Hz
|
Max Stem Dia
|
Motor Class F
|
Rated Current (mA)
|
Number of Hand Wheel
Turns
|
Weight (kg f)
|
1 Phase
|
3 Phase
|
Kg/m
|
90 Deg.
|
mm
|
W
|
110V
|
220V
|
380V
|
440V
|
NA06 |
6 |
14/17 |
22 |
15 |
750 |
450 |
130 |
125 |
8.5 |
11 |
NA09 |
9 |
14/17 |
22 |
25 |
1200 |
580 |
170 |
160 |
8.5 |
11 |
NA15 |
15 |
17/20 |
22 |
40 |
1600 |
950 |
300 |
300 |
10 |
12 |
NA19 |
19 |
17/20 |
22 |
40 |
1600 |
950 |
300 |
300 |
10 |
13 |
NA28 |
28 |
20/24 |
32 |
40 |
1800 |
950 |
330 |
340 |
12.5 |
17 |
NA38 |
38 |
20/24 |
32 |
60 |
2300 |
1300 |
360 |
340 |
12.5 |
18 |
NA50 |
50 |
20/24 |
32 |
90 |
3900 |
1500 |
560 |
570 |
12.5 |
19 |
NA60 |
60 |
24/29 |
42 |
90 |
3900 |
1500 |
560 |
570 |
14.5 |
22 |
NA80 |
80 |
24/29 |
42 |
180 |
4700 |
2150 |
840 |
780 |
14.5 |
23 |
NA100 |
100 |
24/29 |
42 |
180 |
4700 |
2150 |
840 |
780 |
14.5 |
25 |
NA150 |
150 |
72/87 |
75 |
90 |
3900 |
1500 |
560 |
570 |
43.5 |
68 |
NA200 |
200 |
72/87 |
75 |
180 |
4700 |
2150 |
840 |
780 |
43.5 |
70 |
NA250 |
250 |
72/87 |
75 |
180 |
4700 |
2150 |
840 |
780 |
43.5 |
70 |
|
|
|
|
|
|
STANDARD SPECIFICATION |
Enclosure |
Watertight Ingress Protection 67 Nema
4 and 6 |
Ambient
Temperature |
-20¡É to + 70¡É,
150¡É/1hr |
Power
Supply
(60/50 Hz) |
110/220 VAC, 1Phase
380/440 VAC, 3Phase |
Control
Power |
110/220 VAC, 1Phase,
60/50Hz |
Torque
Switches |
2 Open/Close (Except
NA 06, NA 09) |
Limit
Switches |
2 Open/Close, 250
VAC 16A Rating |
Stall
Protection |
Bult-in Thermal
Protection (Open 150¡É¡¾5¡É/Close 97¡É¡¾15¡É) |
Travel
Angle |
90¢ª¡¾5¢ª |
Indicator |
Continuous Position Indicator |
Manual
Override |
Hand/Auto Declutching
Mechanism |
Self
Locking |
Provided by means
of Worm Gearing |
Conduit
Entries |
External Adjustable
Screws |
Space
Heater |
20W (110/220 VAC,
24 VDC) |
Conduit
Entries |
Two PF 3/4" (NPT
3/4") |
Lubrication |
Grease Moly (EP
Type) |
Materials |
Steel, Aluminium
Alloy, All Bronze |
Surface
Treatment |
Anodizing |
External
Coating |
Dry Power, Epoxy
- Polyester, Polyester (TGIC-Free) |
|
|
OPTIONAL SPECIFICATION |
EXP |
Explosion Proof & Watertight Enclosure
Ex d IIB T4 IP 67, EExd IIB T4 (NEMKO) |
DCM |
24V DC MOTOR |
ALS |
Additional
Auxiliary Limit Switches |
EXT |
Travel Angle
120¢ª, 135¢ª, 180¢ª, 270¢ª, 300¢ª |
LCU |
Local Control Unit
Local/Remote Selector Switch
Open/Stop/Close Selector Switch or Push button type |
PIU |
Potentiomerter Unit 1K Ohm. |
CPT |
Current Position
Transmitter
Output : DC 4-20mA |
PCU |
Proportional Control Unit
Power : AC 110/220V 1PH, DC 24V
Input : DC 4-20mA, DC 1-5V, DC 2-10V
Output : DC 4-20mA |
IMS |
Integral Motor
Starter
Reversing Magnet Contacts and Transformer |
|
|
|
|
|
|
|
|
|
TYPE
|
NA06, NA09
|
NA15, NA19
|
NA28, NA38, NA50
|
NA60, NA80, NA100
|
NA150, NA200, NA250
|
Flange
ISO 5211 |
F07
- |
F07
F10 |
F10
F12 |
F12
F14 |
F16
F14 |
A |
70 |
70 |
102 |
125 |
165 |
A' |
- |
102 |
125 |
140 |
*140 |
B |
M8 |
M8 |
M10 |
M12 |
M20 |
B' |
- |
M10 |
M12 |
M16 |
*M14 *M16 |
C |
12 |
15 |
18 |
22 |
30 |
D(MAX) |
22 |
22 |
32 |
42 |
75 |
E |
55 |
57 |
75 |
85 |
100 |
F |
43 |
43 |
52 |
59 |
126 |
G |
2 |
2 |
2 |
2 |
7 |
H |
231 |
261 |
285 |
325 |
325 |
I |
56 |
77 |
83 |
99 |
99 |
J |
175 |
184 |
202 |
226 |
226 |
K |
60 |
60 |
70 |
78 |
78 |
L |
213 |
213 |
250 |
283 |
283 |
M |
273 |
273 |
320 |
361 |
361 |
N |
102 |
120 |
145 |
175 |
266 |
O |
68 |
85 |
99 |
116 |
116 |
P |
113 |
139 |
159 |
191 |
191 |
Q |
181 |
224 |
258 |
307 |
307 |
R |
108 |
108 |
130 |
178 |
178 |
S |
102 |
102 |
125 |
170 |
170 |
T |
|
|
|
|
556 |
U |
|
|
|
|
195 |
X |
|
|
|
|
388 |
Y |
|
|
|
|
16 |
Z |
|
|
|
|
318 |
* : for optional alternative fkanges |
|
|
|
|
|
|
|
|
Piping Pressure : 10kg/§² |
TYPE |
BUTTERFLY
VALVE |
2-WAY BALL
VALVE |
3-WAY BALL
VALVE |
NA06 |
80A |
40A |
|
NA09 |
100A |
50A |
40A |
NA15 |
125A |
65A |
50A |
NA19 |
150A |
80A |
65A |
NA28 |
200A |
100A |
80A |
NA38 |
250A |
|
100A |
NA50 |
|
125A |
|
NA60 |
300A |
150A |
125A |
NA80 |
350A |
|
150A |
NA100 |
|
200A |
|
NA150 |
400/450A |
|
|
NA200 |
500A |
250A |
200A |
NA250 |
600A |
300A |
250A |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|